Technical Data

Type

PROFI LIFTER 500-1

PROFI PULLER 800-1

Nominal pressure (required static pressure)

bar

6

6

Lifting capacity in the last layer

kg

500

-

Lifting capacity in the first layer

kg

750

-

Pulling capacity in the last layer

kg

-

530

Pulling capacity in the first layer

kg

-

800

Max. number of rope layers

 

5

5

Max. motor power

kW

1,0

1,0

Air connection

 

G ½

G ½

Air consumption at nominal load, lifting

m³/min

1,2

1,1

Air consumption at nominal load, lowering

m³/min

1,5

-

Hose size (ø inside)

mm

13

13

Rope drum diameter

mm

76

76

Rope diameter

mm

5,5 - 7,0

5,5 - 7,0

Minimum breaking force of rope

kN

24,5

23,5

Weight (without rope, with control)

kg

29,3

31,2

Control length

m

1,5

1,5

Noise pressure level at nominal load - lifting or pulling¹

dB(A)

85

87

Noise pressure level at nominal load - lowering¹

dB(A)

89

-

¹ measured at 1 m distance according to DIN 45635 part 20

 

Dimensions

 

 

Performance Data

PROFI LIFTER 500-1 (1 Am)
Rope diameter 6 mm

Speeds [m/min]

Lifting

Lowering

Rope Layer

1. Layer

5. Layer

1. Layer

5. Layer

Load condition [kg]

0

17,7

28,2

13,3

21,2

250

14,1

19,0

16,6

29,6

500

10,4

9,8

19,9

37,9

750

6,8

-

23,2

-

PROFI PULLER 800-1 (1 Am)
Rope diameter 6 mm

Speeds [m/min]

Pulling

Unwinding

Rope Layer

1. Layer

5. Layer

1. Layer

5. Layer

Load condition [kg]

0

17,7

28,2

13,3

21,2

300

13,4

17,1

-

-

530

10,0

8,1

-

-

800

6,1

-

-

-

 

Characteristic Load Curves PROFI LIFTER 1100-1 and PROFI PULLER 1750-1

 

 

Rope Capacities

PROFI LIFTER 500-1 and PROFI PULLER 800-1

Rope layer

Rope diameter

mm

5,5

6,0

6,5

7,0

1st

m

9,1

8,4

7,7

7,1

1st and 2nd

m

20,4

18,8

17,5

16,4

1st, 2nd and 3rd

m

33,0

30,6

28,7

27,0

1st, 2nd, 3rd and 4th

m

46,9

43,8

41,2

39,0

1st, 2nd, 3rd, 4th and 5th

m

62,2

58,3

-

-

Recommended rope diameter: 6,0 mm

Note: The calculated possible rope storage capacities depending upon the rope diameter and rope layers used are listed in the tables. The retention of the required three safety windings was also taken into account.

Issue: 16.04.2007